Leave Your Message
Products Categories
Featured Products

YB(W) - 12/0.4 Outdoor Prefabricated Substation of Non-metallic Series

YB(W)-12/0.4 box type transformer substation is the compact distributing equipment comprising high voltage switchgear, distributing transformer,low voltage distributing equipment and electric energy measurement equipment,etc,which are arranged into an organic whole according to the certain circuit scheme. This equipment is the complete transformer substation used for receiving and distributing electric energy at threephase Ac system of rated voltage 10/0.4kV in the following fields such as urban public distributing, tall building, residual area, industrial and mining enterprise,oil fields, temporary construction for project. Lt’s technical performance completely meets the requirements stipulated in the standards ZBK 4001-89 and SD 320-89.

    Product introduction

    The name "12/0.4" provides insight into the transformation ratio, where 12 kV represents the high voltage side and 0.4 kV represents the low voltage side.  Additionally, the "W" designation may indicate that it is a weatherproof or outdoor-rated device, ensuring its reliability and functionality in outdoor environments.

    One of the main features of this substation is its non-metallic construction.  Unlike traditional metal casings, the casing of the substation is made of non-metallic materials.  This design offers several advantages, including corrosion resistance, light weight, and cost-effectiveness.  The use of non-metallic materials increases the durability and lifespan of the substation, making it a reliable choice for outdoor applications.

    YB(W)-12/0.4 outdoor box-type substation is specially designed to meet the needs of modern power distribution systems.  Its efficient transformation ratio and non-metallic construction make it a valuable asset for utility companies, industrial facilities and infrastructure projects.  By providing reliable, durable high-voltage power step-down solutions, substations help distribute power efficiently and safely to end users.

    Basic technical parmeters

    Item

    On the sidle of high voltage

    Transformer

    On the side of low voltage

    Rated working capability

     

    50-1250kvA

     

    Rated working voltage

    10kV

    10/0.4 kV

    0.4 kV

    Rated working current

    400-630A

     

    630-2500A

    Rated short-circuit breaking
     current

    50kA

     

    25-4kA

    Rated marking current

    40kA

     

     

    Rated thermal stable current (effective value)

    16kA/2S

     

    15、30kA/1S

    1 min power frequency withstand voltage

    To earth 42kV

    Dry type 28kV

    2.0kv,2.5kV

    Between open contacts 48kV

    Oil immersed 35kV

     

    Lightning impulse withstand voltage

    To earth 75kV

    75kV

     

    Between open contacts 85kV

     

     

    Protection level

    IP3X

    IP2X

    IP3X

    Noise

    Oil immersed transformer55dB

    Dry type transformer 65dB

    Leave Your Message